首页> 外文会议>Particle Accelerator Conference >Klystron-modulator system performance for the advanced photon source linear accelerator
【24h】

Klystron-modulator system performance for the advanced photon source linear accelerator

机译:KlyStron-调制器系统性能,用于高级光子源线性加速器

获取原文

摘要

The S-band linear accelerator (linac), which was built to be the electron source and the front end of the Advanced Photon Source (APS) injector, is now also being used to support a low-energy undulator test line (LEUTL) to drive a free-electron laser (FEL). The APS linac system employs five units of pulsed high-power klystrons (35-MW class) as the main rf sources. The matching pulse modulators provide high-voltage pulses running at 280 kV and 300 A with 3.5-μs pulse width and a nominal pulse repetition rate of 30 Hz. The system availability of the entire APS linac during the last run period of calendar year 2000 was estimated to be slightly over 95%. We present a discussion of the reliability and various fault statistics of the klystron-modulator system together with the key features of the system hardware.
机译:建立为先进光子源(APS)喷射器的电子源和前端的S频带线性加速器(LINAC)现在也用于支撑低能量波动器测试线(leutl)驱动自由电子激光器(FEL)。 APS LINAC系统采用五个单位的脉冲大功率klystrons(35 MW类)作为主要的RF源。匹配脉冲调制器提供以280 kV和300a运行的高压脉冲,脉冲宽度为3.5μs脉冲宽度和30Hz的标称脉冲重复率。 2000年日历年次上次运行期间整个APS LINAC的系统可用性估计略高于95%。我们讨论了Klystron调制器系统的可靠性和各种故障统计以及系统硬件的关键特征。