The Los Alamos Neutron Scattering Center (LANSCE) proton storage ring (PSR) control system upgrade is complete. In previous work, much of a PDP-11-based control system was replaced with the Experimental Physics and Industrial Control System (EPICS) controls. Several parts of the old control system which used a VAX for operator displays and direct access to a CAMAC serial highway still remained. The old system was preserved as a "fallback" if the new EPICS-based system had problems. The control system upgrade completion included conversion of several application programs to EPICS-based operator interfaces, moving some data acquisition hardware to EPICS Input-Output Controllers (IOCs), and the implementation of new gateway software to complete the overall control system interoperability. Many operator interface (OPI) screens, written by LANSCE operators, have been incorporated in the new system. The old PSR control system hardware was removed. The robustness and reliability of the new controls obviated the need for a fallback capability.
机译:洛斯阿拉莫斯中子散射中心(LANSCE)质子储存环(PSR)控制系统升级完成。在以前的工作中,许多基于PDP-11控制系统用的实验物理和工业控制系统(EPICS)控制代替。它使用了VAX操作员显示和直接访问CAMAC串行公路旧的控制系统等几部分依然存在。旧系统被保留下来作为“后备”如果基于EPICS新的系统有问题。该控制系统升级完成包括基于流式细胞操作界面的几个应用程序转换,把一些数据采集硬件EPICS输入输出控制器(IOC的),以及新网关软件的实施,完成整个控制系统的互操作性。许多操作界面(OPI)屏幕,通过LANSCE运营商写的,已在新系统被纳入。除去旧的PSR控制系统的硬件。新的控件的稳健性和可靠性,消除了回退能力的需要。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号