首页> 外文会议>Symposium on Fusion Engineering >Use of near-infrared detector to sense RF antenna heating
【24h】

Use of near-infrared detector to sense RF antenna heating

机译:使用近红外探测器感测RF天线加热

获取原文

摘要

The three antennas used for ion cyclotron heating (ICH) experiments on DIII-D have experienced localized heating of the Faraday shield rods during plasma operations which has resulted in some melting. This melting is of great concern not only because of the damage it does to the rf system's ability to deliver RF to the plasma, but because of its potential to contaminate the plasma during a shot and cast the experimental results from the shot into question. A real-time sensor to detect the temperature of the antennae during plasma operations is described. The sensor uses an avalanche photodiode (APD) with sensitivity from 0.4 to 1.0 /spl mu/m to monitor the temperature of the antennae. Calculations for the detector sensitivity based on Planck's law are compared with experimental results and detector data taken during plasma operations are presented.
机译:用于离子回旋加热的三个天线(ICH)DIII-D的实验已经在等离子体操作期间经历了法拉第盾牌杆的局部加热,这导致了一些熔化。这种熔化是非常令人担忧的,不仅因为它对RF系统提供RF到等离子体的能力而造成的损害,而且因为它可能在射击期间污染等离子体并施放实验结果,并击中了问题。描述了在等离子体操作期间检测天线温度的实时传感器。该传感器使用雪崩光电二极管(APD),灵敏度为0.4至1.0 / SPL MU / M来监测天线的温度。将基于Planck定律的探测器灵敏度的计算与实验结果进行了比较,并提出了在等离子体操作期间拍摄的检测器数据。