首页> 外文会议>Conference on NCPV photovoltaics program review >Performance Losses in Rooftop-Mounted PV Modules from Long-Term Environmental Exposure at Las Cruces, New Mexico
【24h】

Performance Losses in Rooftop-Mounted PV Modules from Long-Term Environmental Exposure at Las Cruces, New Mexico

机译:从新墨西哥州拉斯克鲁克的长期环境暴露的屋顶安装光伏模块中的性能损失

获取原文

摘要

Forty-eight PV modules of four different types were instrumented and tested monthly for 3 years to measure and record the performance effects of environmental exposure. Two modules were removed from each set of 12 as a control and for "initial" characterization. As a secondary goal, the effects of mounting topology (open rack, integrated roof, conventional standoff mount) were also closely monitored. Current-voltage (I-V) curve data were archived and normalized according to accepted methods. The EVA pottant in all modules monitored was discolared to a deep yellow-to-brown color from prior exposures before the monitoring was begun. Modules showing observable performance degradation were removed from their mounts and prepared for in-depth analysis. During the 3-year monitoring period, 4 of the 10 Solarex a-Si modules stopped producing, 3 of the 10 Solarex MIT pc-Si modules lost from 5percent to 10percent efficiency, and 1 Mobil Ra-180 pc-Si module lost about 10percent efficiency. For all of the other modules, a loss of less than 1percent per year was recorded, which included all 10 of the Sovonics P-101 a-Si modules.
机译:每月有四十八种不同类型的PV模块进行仪器和测试3年,以衡量和记录环境暴露的性能影响。将两个模块从每组12组中除去,作为对照和“初始”表征。作为次要目标,也密切监测安装拓扑(开放式架,集成屋顶,常规支架安装架)的影响。根据可接受的方法归档和归一化电流 - 电压(I-V)曲线数据。在监测开始之前,所有模块中监测的EVA百叶菌都令人褪色为从先前曝光的深黄色到棕色。从它们的安装座中除去显示可观察性能降解的模块,并准备用于深入分析。在3年监测期间,10个Solarex A-Si模块中的4个停止生产,10个Solarex MIT PC-Si模块中的3个损失从5%到10个效率,1个Mobil RA-180 PC-Si模块丢失了10%效率。对于所有其他模块,记录了每年损失小于1的损失,其中包括所有10个Sovonics P-101 A-Si模块。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号