Locating Partial Discharge (PD) sources accurately in power transformers is of great importance for maintenance scheduling, maintenance efficiency and even operational risk analysis. Techniques for locating the source of PD are constantly a hot research topic. Location algorithm is one of the research contents. At present major problems existing in locating algorithms are being sensitive to time-delay error, local convergence or divergence and a large amount of computational time. To solve these problems, Newton iterative algorithm based on the Gauss method is suggested in this paper. At the end, PD location experiments and calculations were carried out on a real power transformer to verify the algorithm.
机译:在电力变压器中精确定位局部放电(PD)源对于维护调度,维护效率甚至操作风险分析非常重要。用于定位PD源的技术是不断的热门研究主题。位置算法是研究内容之一。目前在定位算法中存在的主要问题对时延误误差,局部收敛或发散以及大量的计算时间敏感。为了解决这些问题,本文提出了基于高斯方法的牛顿迭代算法。最后,在实际电力变压器上执行PD位置实验和计算以验证算法。