首页> 外文会议>International conference on wind engineering >Wind tunnel tests of a cable supported roof of a stadium
【24h】

Wind tunnel tests of a cable supported roof of a stadium

机译:风隧道测试体育场的电缆支撑屋顶

获取原文

摘要

This paper presents the results of wind tunnel tests of Silesian Stadium in Chorzow. Tests were carried out at the Institute of Aviation in Warsaw. Model, made to 1:150 scale, was set up behind a turbulent flow development system. Experimental data were obtained by measuring the values of average and instantaneous fluctuations of pressure coefficient C_p on the roof of this stadium. It has been found that for the same directions of wind maximum local values of the mean pressure coefficient C_p are approximately -2.0. Instantaneous fluctuations of the pressure coefficient may be about 3.5 times higher than the average pressure values. The intensity of the pressure coefficient fluctuations falls mainly in the range from 0.25 to 0.4, except in some points, where the average values of the pressure coefficient are very small. Autocorrelation functions and spectra were also obtained.
机译:本文介绍了Chorzow中Silesian Stadium风洞测试的结果。测试是在华沙航空研究所进行的。模型为1:150规模,设置在湍流开发系统后面。通过测量该体育场屋顶上的压力系数C_P的平均和瞬时波动的值来获得实验数据。已经发现,对于平均压力系数C_P的相同风的最大局部值约为-2.0。压力系数的瞬时波动可以比平均压力值高约3.5倍。除了一些点之外,压力系数波动的强度主要落在0.25至0.4的范围内,其中压力系数的平均值非常小。还获得了自相关函数和光谱。

著录项