AC Voltmeters and AC/DC Transfer Standards can cause significant loading errors when measuring many types of sources at the mV level and frequencies above 100 kHz and also below 100 kHz when used with high resistance current shunts. This paper explains the sources of this error, how to measure it and some typical loading errors to be expected with Fluke AC/DC Transfer Standards. This paper is a follow up to a preliminary paper on this subject given at NCSL 97 and offers refinements and new information.
机译:AC电压表和AC / DC转移标准可能会导致在使用高电阻电流分流器时测量MV水平的许多类型的源,并且在100kHz以上100 kHz的频率时造成显着的负载误差。本文解释了该误差的来源,如何测量它以及对Fluke AC / DC转移标准预期的一些典型装载错误。本文是在NCSL 97上给出的此主题的初步纸张的后续纸张,并提供细化和新信息。