This paper describes the progress with the NPL Josephson junction array voltage standards. The JJAVS achieves a system uncertainty of 2 parts in 10~(9) and an uncertainty for measurement of zener reference standards of 11 parts in 10~(9) for a confidence level of k(velence)2. The system is also capable of calibrating state-of-the-art digital voltmeters (DVMs). A two Josephson array system has also been developed for the calibration of resistive voltage dividers (RVDs) with the intention of simplifying the calibration process and enabling the calibration of any ratio that is capable of measuring the ratio to 1 in 10~(7).
机译:本文介绍了NPL Josephson结阵列电压标准的进展。 JJAVS在10〜(9)中的2份的系统不确定度和测量10〜(9)中的齐纳参考标准的不确定度,以置于K(柔滑节)2的置信水平。该系统还能够校准最先进的数字电压表(DVM)。还开发了两个约瑟夫森阵列系统,用于校准电阻分配器(RVDS),意图简化校准过程,并能够校准能够将比率测量到10〜(7)中的比率。