The mechanical characterisation of Ceramic Matrix Composites (CMCs) poses challenges because of the high testing temperature and their particular material structures. Choosing the correct specimen geometry is critical to obtain valid test results. This is particularly true for composite materials which have high strength in the fibre direction, but low strength in the transverse direction and in shear mode. In this paper, a generic tensile specimen shape is investigated by varying four of itsgeometric parameters. A finite element model is built to determine the stress field, which is compared with the material strengths to ascertain failure mode and location. Recommendations arc made for the parameters to ensure tensile failure within gaugesection. They ire checked using both CFRP and CMC specimens. Some of the muddling issues are also discussed.
机译:由于高测试温度及其特定的材料结构,陶瓷基复合材料(CMC)的机械表征构成挑战。选择正确的样品几何是至关重要的,以获得有效的测试结果。对于在纤维方向上具有高强度的复合材料,但尤其如此,但在横向方向上的低强度和剪切模式。在本文中,通过改变四个ItsGeometric参数来研究通用拉伸样品形状。建立有限元模型以确定应力场,与材料强度进行比较以确定故障模式和位置​​。建议适用于参数,以确保仪表中的拉伸故障。他们使用CFRP和CMC标本检查。还讨论了一些混乱的问题。