首页> 外文会议>World conference on structural control >Passive damper control of the 76-story wind-excited benchmark building
【24h】

Passive damper control of the 76-story wind-excited benchmark building

机译:76层风吹基准建筑的被动阻尼控制

获取原文

摘要

In this paper, the sequential search method is used to determine optimal locations and capacities of passive dampers in the 76-story wind-excited benchmark building, such that a specified performance, such as maximum rms floor acceleration, is satisfied. It is found that the sequential search method is quite effective in determining locations and capacities of dampers. Further, a method for the design of capacities of passive dampers, which is based on active control theories, is also presented and its application to wind-excited building is demonstrated by numerical simulation results.
机译:在本文中,顺序搜索方法用于确定76层风激的基准建设中无源阻尼器的最佳位置和能力,使得满足指定的性能,例如最大RMS底层加速度。发现顺序搜索方法在确定阻尼器的位置和容量方面非常有效。此外,还提出了一种用于设计基于主动控制理论的被动阻尼器的能力的方法,并通过数值模拟结果证明了其对风力激发建筑的应用。