Potentiometric oxygen sensors with LBE/PbO and In/In2O3 reference electrodes coupled with yttria partially stabilized zirconia (YPSZ) have been developed for use in liquid lead-bismuth eutectic (LBE) over the temperature range from 200 to 450 °C. The performance of sensors with LBE/PbO and m/ln2O3 reference electrodes was evaluated comparing the oxygen activity measured in oxygen saturated LBE (from 200 to 450 °C) with these sensors to the one measured by sensors with Bi/Bi2O3 and air/LSM (strontium-doped lanthanum manganite) electrodes, using same solid electrolyte and measurement setup. The sensors with LBE/PbO and In/In2O3 reference electrode performed well down to 200 °C while the sensor with Bi/Bi2O3 showed significant deviations at 200 °C.
机译:具有LBE / PBO和/ IN2O3的电位氧传感器,与YtTria部分稳定的氧化锆(YPSZ)开发用于液体引导 - 铋的温度范围为200至450℃。评价具有LBE / PBO和M / LN2O3参考电极的传感器的性能将在氧饱和LBE(从200至450℃)中测量的氧活与这些传感器进行比较,以通过BI / BI2O3和空气/ LSM测量的传感器测量(掺杂硼镧锰铁)电极,使用相同的固体电解质和测量设置。具有LBE / PBO和/ IN2O3参比电极的传感器在200°C的传感器显示出均匀的传感器显示出良好至200°C。