A Probabilistic Safety Assessment (PSA) for Point Lepreau Generating Station has been completed as part of the plant Refurbishment Project. The main objective is to provide insights into plant safety design and performance, including the identification of dominant risk contributors and the comparison of options for reducing risk. The scope of this assessment covers Level 1 and 2 PSA and includes internal events for full power and shutdown, and internal fires, floods, and seismic events for full power operation. Internal fire analysis established potential fire scenarios by identifying their fire characteristics (ignition sources, combustibles, fire protection features, and location of PSA-credited components). The fire-induced severe core damage frequency (SCDF) was estimated for fire scenarios that were not screened out. Internal flood analysis established potential flood scenarios by identifying the flooding source, propagation, and effect on PSA-credited equipment. The flood-induced SCDF was estimated for each flood scenario. PSA-based seismic margin assessment measured the robustness of the plant to withstand earthquakes of a given g-level. This paper describes the major steps in performing Level 1 ASQ for internal fire, flood, and seismic events and discusses the key results of this study.
机译:Point Lepreau生成站的概率安全评估(PSA)已完成作为工厂翻新项目的一部分。主要目标是提供植物安全设计和绩效的见解,包括识别占主导地位风险贡献者以及降低风险的选项的比较。该评估的范围涵盖1级和2级PSA,包括全电力和关闭的内部事件,以及用于全电力操作的内部火灾,洪水和地震事件。内部火灾分析通过识别其火灾特性(点火源,可燃物,消防功能和PSA贷记组件的位置)建立了潜在的火灾情景。估计未筛选的火灾情景估计火灾诱导的严重核心损伤频率(SCDF)。内部洪水分析通过识别洪水源,传播和对PSA贷记设备的影响建立了潜在的洪水情景。每次洪水情景估计洪水引起的SCDF。基于PSA的地震保证金评估测量了植物的稳健性,以承受给定的G级地震。本文介绍了内部火灾,洪水和地震事件执行1级ASQ的主要步骤,并讨论了本研究的关键结果。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号