摘要

This paper reports the analysis results of the solar energy resource and potential electricity generating capacity from building-integrated photovoltaics (BIPV) systems in Hong Kong. The monthly average daily solar radiation on a horizontal surface and the daily sum distributions of solar radiation show that the solar radiation intensity is quite high in Hong Kong except the wet period from January to March. The mean annual global radiation is 4646.8 MJ/m/sup 2/. The potential electricity generating capacity from BIPV systems is estimated to be 10.5 TWh which is about 35% of the total annual electricity supply (29.9 TWh) in Hong Kong in 1995 if the shadow facades of the high-rise buildings are excluded. The BIPV electricity prices are estimated and compared with the local grid electricity prices. The results illustrate a bright future for BIPV applications in the next century in Hong Kong.
机译:本文报道了香港建筑集成光伏(BIPV)系统的太阳能资源和潜在发电能力的分析结果。每月平均日常太阳辐射水平表面和日常太阳辐射的每日和分布表明,在香港的太阳辐射强度除了从1月到3月的潮湿时期。平均年度全球辐射为4646.8 mj / m / sup 2 /。 BIPV系统的潜在发电能力估计为10.5 TWH,1995年香港总电力供应量(29.9 TWH)的35%为1995年,如果被排除在外的高层建筑的影子立面。 BIPV电价估计并与当地电网价格进行比较。结果说明了在香港下一个世纪的BIPV应用的光明未来。