【24h】

STRESSED OXIDATION OF C/SiC COMPOSITES

机译:胁迫氧化C / SiC复合材料

获取原文

摘要

Constant load, stressed oxidation testing was performed on T-300 C/SiC composites with a SiC seal coat. Test conditions included temperatures ranging from 350 deg C to 1500 deg C at stresses of 69 MPa and 172 MPa (10 and 25 ksi). The coupon subjected to stressed oxidation at 550 deg C/69 MPa for 25 hours had a room temperature residual strength one-half that of the as-received coupons. The coupon tested at the higher stress and all coupons tested at higher temperatures failed in less than 25 hr. Microstructural analysis of the fracture surfaces, using SEM (scanning electron microscopy), revealed the formation of reduced cross-sectional fibers with pointed tips. Analysis of composite cross-sections show pathways for oxygen ingress. The discussion will focus on fiber/matrix interphase oxidation and debonding as well as the formation and implications of the fiber tip morphology.
机译:恒定载荷,胁迫氧化测试用SiC密封涂层对T-300 C / SiC复合材料进行。试验条件包括在69MPa和172MPa(10和25 ksi)的应力下从350℃至1500℃的温度范围内。在550℃/ 69MPa下经过压力氧化的优惠孔25小时的室温残余强度为AS接收的试样的一半。在较高的应力和在较高温度测试的所有优惠券的优惠券在较高温度下测试的所有优惠券在少于25小时内失效。使用SEM(扫描电子显微镜)的断裂表面的微观结构分析显示,尖端尖端的横截面纤维的形成形成。复合横截面分析氧气入口途径。讨论将专注于纤维/基质间氧化和剥离以及纤维尖端形态的形成和影响。