The transducers employed to measure the concentration of CO{sub}2 launched to the atmosphere are only calibrated in a static manner. Thus, the transient effects of the flow of such gas are not properly recorded. This study aims at presenting a new methodology to characterize the dynamic performance of carbon dioxide transducers, and to experimentally determine its transference function. To achieve this goal, a device was developed in which the variables influencing the measures are controlled, allowing the transducer's dynamic response to be assessed.
机译:采用用于测量向大气发射的CO {Sub} 2的浓度的换能器仅以静态校准。因此,不正确地记录这种气体流动的瞬态效应。本研究旨在提出一种新方法来表征二氧化碳传感器的动态性能,并通过实验确定其转移功能。为实现这一目标,开发了一种设备,其中控制影响措施的变量,从而允许换能器对进行的动态响应进行评估。