首页> 外文会议>International Power Modulator Symposium >Partial Discharge Tests and Characterization of the Advanced Photon Source Linac Modulator Cables
【24h】

Partial Discharge Tests and Characterization of the Advanced Photon Source Linac Modulator Cables

机译:先进的光子源LINAC调制电缆的局部放电测试和表征

获取原文

摘要

The Advanced Photon Source (APS) linac modulators are PFN-type pulsers with switch-mode charging power supplies (PSs). The PS and the PFN are connected to each other by 15 feet of 100-kV X-ray cable, with the PFN end of the cable terminated with a connector that was confirmed partial-discharge (PD)-free up to 38 kV ac (53.5 kV peak). Another end of the cable is terminated with a connector that was designed by the PS manufacturer and cannot easily be replaced with another type of connector, since part of it is located inside the densely packed PS. PD tests of the cables with this type of connector show that the PD inception voltages (PDIVs) in different cables turn out to be located within a wide voltage range: 21 to 27 kV ac that corresponds to 29 to 38 kV peak. In order to evaluate the insulation condition of the modulator cables, detect insulation deterioration, and ensure failure-preventing equipment maintenance, over the last two years the PDIVs of all high-voltage (HV) cables in use in the modulators have been tested about every three and a half months. Before the tests, all cables were removed from the equipment, carefully cleaned, inspected, and regreased. The tests were performed using a 40-kV PD detector. The test results show that: 1) The PDIVs remain almost unchanged in all tested cables. 2) From test to test, the PDIV of any particular cable may slightly oscillate around some average value. This possibly depends on the connector regreasing) There is no direct evidence of cable insulation deterioration during more than two years of operation under voltage higher than the PD inception level.
机译:高级光子源(APS)LINAC调制器是具有开关模式充电电源(PSS)的PFN型脉冲器。 PS和PFN通过15英尺的100 kV X射线电缆彼此连接,电缆的PFN端终止,该连接器被确认的局部放电(PD) - 完全高达38 kV AC( 53.5 kV峰)。电缆的另一端终止于由PS制造商设计的连接器,不易用另一种类型的连接器更换,因为它的一部分位于密集包装的PS内。具有这种类型的连接器的电缆的PD测试表明,不同电缆中的PD初始电压(PDIV)转向位于宽电压范围内:21至27 kV AC,对应于29至38 kV峰值。为了评估调制器电缆的绝缘状况,检测绝缘劣化,并确保防止设备维护,在过去两年中,调制器中使用的所有高压(HV)电缆的PDIV都已测试三个半月。在测试之前,所有电缆都被从设备中取出,仔细清洁,检查,重新抛弃。使用40kV PD检测器进行测试。测试结果表明:1)PDIV在所有测试电缆中几乎保持不变。 2)从测试测试,任何特定电缆的PDIV都可以略微振荡在某个平均值。这可能取决于连接器Regeaping)在高于PD初始电平的电压下超过两年的操作期间,没有直接证据了电缆绝缘劣化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号