Partial Discharge Tests and Characterization of the Advanced Photon Source Linac Modulator Cables

机译:先进光子源直线加速器调制器电缆的局部放电测试和表征

获取原文

摘要

The advanced photon source (APS) linac modulators are PFN-type pulsers with switch-mode charging power supplies (PSs). The PS and the PFN are connected to each other by 15 feet of 100-kV x-ray cable, with the PFN end of the cable terminated with a connector that was confirmed partial-discharge (PD)-free up to 38 kV ac (53.5 kV peak). Another end of the cable is terminated with a connector that was designed by the PS manufacturer and cannot easily be replaced with another type of connector, since part of it is located inside the densely packed PS. PD tests of the cables with this type of connector show that the PD inception voltages (PDIVs) in different cables turn out to be located within a wide voltage range: 21 to 27 kV ac that corresponds to 29 to 38 kV peak. In order to evaluate the insulation condition of the modulator cables, detect insulation deterioration, and ensure failure-preventing equipment maintenance, over the last two years the PDIVs of all high-voltage (HV) cables in use in the modulators have been tested about every three and a half months. Before the tests, all cables were removed from the equipment, carefully cleaned, inspected, and regreased. The tests were performed using a 40-kV PD detector. The test results show that: 1) The PDIVs remain almost unchanged in all tested cables. 2) From test to test, the PDIV of any particular cable may slightly oscillate around some average value. This possibly depends on the connector regreasing technique. 3) There is no direct evidence of cable insulation deterioration during more than two years of operation under voltage higher than the PD inception level
机译:先进的光子源(APS)线性加速器调制器是具有开关模式充电电源(PS)的PFN型脉冲发生器。 PS和PFN通过15英尺的100 kV X射线电缆相互连接,电缆的PFN端部终止于一个连接器,该连接器已确认在不超过38 kV ac的条件下无局部放电(PD)( 53.5 kV峰值)。电缆的另一端用PS制造商设计的连接器端接,由于一部分位于密密麻麻的PS内部,因此不易用另一种类型的连接器替换。使用这种类型的连接器进行的电缆的PD测试表明,不同电缆中的PD起始电压(PDIV)处于很宽的电压范围内:21至27 kV ac,对应于29至38 kV峰值。为了评估调制器电缆的绝缘状况,检测绝缘劣化并确保预防故障的设备维护,在最近两年中,已对调制器中使用的所有高压(HV)电缆的PDIV进行了测试。三个半月。测试前,将所有电缆从设备上卸下,仔细清洁,检查并重新涂脂。使用40 kV PD检测器进行测试。测试结果表明:1)在所有测试的电缆中,PDIV几乎保持不变。 2)从测试到测试,任何特定电缆的PDIV可能会在某个平均值附近轻微振荡。这可能取决于连接器的润滑技术。 3)没有直接证据表明在高于PD起始电压的电压下运行两年以上,电缆绝缘性能会下降

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号