An in vitro time study of distensibility in porcine aortas using high resolution X-ray CT

机译:高分辨率X射线CT的猪主动脉致敏性的体外时间研究

获取原文

摘要

Porcine aortas have been used extensively for medical research because of their availability and similarities to human aortas. The elastic properties of porcine aortas have also been studied and quantified, yet there has been no initiative to study the effect of time on the elastic properties of in vitro porcine aortic specimens when pressurized with humidified air, which the authors use as contrast for the arterial wall when X-ray imaging (CT) is used to determine the effect of pressure on aortic dimensions. These experiments were designed to clarify whether the use of humidified air to pressurize the specimens affects the elastic properties of the tissue over a period of time. Seven porcine aortas (four thoracic and three abdominal) studied. The specimens were cleaned of adipose tissue and made pressure tight by tying off the side branches. Each specimen was pressurized from 4 to 24 kPa with humidified air and imaged on days 0, 3, 5 and 7 by mounting the aortas in a high-resolution laboratory computed tomography (CT) scanner. Between imaging sessions the aortas were stored in a saline solution and refrigerated at 5/spl deg/C. Distensibility was then calculated from luminal perimeter measurements obtained from 2-dimensional cross-sectional slices through the aorta at six different pressures. Approximately 50 minutes were needed to acquire each set of data. The lumen perimeter increased after each imaging session, presumably due to creep. The distensibility of the thoracic aortas decreased in the range of 4.2-12.7% over the duration of the experiments and their perimeter-pressure curves were linear. The distensibilities of the abdominal aortas varied considerably from an increase of 16.5% to a decrease of 58%, and their perimeter-pressure curves were nonlinear. The wide range in results, particularly with the abdominal aortas, indicates that further studies are required.
机译:由于其与人类主动脉的可用性和相似性,猪主动脉已广泛用于医学研究。猪主动脉的弹性性能也进行了研究和量化,但是当有加湿空气,作者作为对比使用的动脉加压一直没有主动研究了体外猪主动脉标本的弹性性质的时间的影响X射线成像(CT)用于确定压力对主动脉尺寸的影响时。这些实验旨在阐明使用加湿空气是否加压样品,在一段时间内影响组织的弹性性质。研究了七种猪主动脉(四个胸部和三个腹部)。通过捆扎侧枝清洁脂肪组织并使压力紧压。通过在高分辨率实验室计算断层扫描(CT)扫描仪中,通过将Aortas安装在0,3,5和7天,每次,每种样品从4-24kPa加压,并在0,3,5和7天上成像。在成像季节之间将主体储存在盐水溶液中并在5 / SPL DEG / C处冷藏。然后通过在六种不同压力下通过主动脉从二维横截面切片获得的腔横截面测量来计算可扩展性。需要大约50分钟来获取每组数据。每个成像会话后,腔周长增加,可能是由于蠕变。在实验期间,胸主动脉的胸部主动脉的可扩展性在4.2-12.7%的范围内,其周边压力曲线是线性的。腹部主动脉的延伸性从增加的增加16.5%至58%的增加,它们的周边压力曲线是非线性的。结果中的宽范围,特别是腹主动脉,表明需要进一步的研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号