4 MW upgrade to DIII-D FWCD system: system commissioning and initial operation

机译:4 MW升级到DIII-D FWCD系统:系统调试和初始操作

获取原文

摘要

The initial installation of the 4 MW fast wave current drive (FWCD) upgrade started in 1992 with the purchase of two ABB/Thomcast AG RF power amplifiers. These amplifiers cover the frequency range 30 MHz to 120 MHz. A maximum output power of over 2 MW between 30 MHz and 80 MHz and 1 MW at 120 MHz were the specification requirements. The system as installed is comprised of the two mentioned RF amplifiers, coaxial transmission and matching components, RF phase and amplitude monitoring, and a SUN SparcStation 10 control system. Due to various reasons almost every major component in the system required redesign and engineering in order to meet the system requirements. The failures, probable cause and the final redesigns will be discussed as well as some thoughts on how better to specify system requirements for future systems.
机译:初始安装4 MW快波电流驱动器(FWCD)升级于1992年开始购买两个ABB / Thomcast AG RF功率放大器。这些放大器覆盖了30 MHz至120 MHz的频率范围。最大输出功率为30 MHz和80 MHz之间,120 MHz的1兆瓦的最大输出功率是规格要求。安装的系统由两个提到的RF放大器,同轴传输和匹配组件,RF相位和幅度监测以及SUN SPARCSTATION 10控制系统组成。由于各种原因,系统中的每个主要组件都需要重新设计和工程,以满足系统要求。将讨论故障,可能的原因和最终重新设计以及一些关于为未来系统指定系统要求的更好的思考。