首页> 外文会议>Ozone world congress >OZONE GENERATION BY CORONA DISCHARGE - STUDY OF OPTIMUM OPERATING CONDITIONS AND REMEDIAL MEASURES FOR FAILURE PREVENTION
【24h】

OZONE GENERATION BY CORONA DISCHARGE - STUDY OF OPTIMUM OPERATING CONDITIONS AND REMEDIAL MEASURES FOR FAILURE PREVENTION

机译:通过电晕outts outting的臭氧生成 - 用于预防失败的最佳运行条件和补救措施

获取原文

摘要

Ozone generation by corona discharge in tubular reactors are beset with occasional problems leading to failure of equipment. In this article, a discharge operating point for optimum working is defined as the knee of the ozone curve versus applied kilovolts. To operate with proper control of parameters and to check for creepage and sparking, a continuous monitoring with trend analysis is performed using a microcontroller board, which also serves to control the voltage applied and issue alarms when so required.
机译:管状反应器中的电晕放电的臭氧产生偶尔有偶尔的问题导致设备失效。在本文中,用于最佳工作的放电操作点被定义为臭氧曲线与应用千伏的膝关节。为了操作对参数的正确控制并检查爬电和火花,使用微控制器板进行趋势分析的连续监控,该电路板还用于控​​制所施加的电压并在需要时发出警报。