If a voltmeter is connected across the two ends of the shaft of a rotating electrical machine, a small voltage can normally be detected. In many cases this voltage is too small to cause problems, but if it reaches a level at which significant current starts to flow through bearings or other components attached to the shaft, then precautions such as insulating the bearings will be required. A brief review of the various mechanisms for the generation of shaft voltage is given, and one of these, involving a nonuniform air gap and alternating flux linkages with the shaft, is considered in detail for a particular machine. Simplified theory is presented together with a calculation procedure that is tested against measured results.
机译:如果电压表在旋转电机的轴的两端连接,则通常可以检测到小电压。在许多情况下,该电压太小而无法引起问题,但是如果它达到电流的电平,则需要通过附接到轴的轴承或其他部件的电平,然后需要诸如绝缘轴承的预防措施。给出了对产生轴电压的各种机制的简要介绍,并且对于特定机器,详细考虑了其中一种,涉及与轴的非均匀空气间隙和交替的通量键合。简化的理论与测试程序一起呈现,该计算程序针对测量结果进行了测试。