首页> 外文会议>IEEE international caracas conference on devices, circuits and systems >Consideration of the transient configurations in the optimal coordination problem of directional overcurrent relays
【24h】

Consideration of the transient configurations in the optimal coordination problem of directional overcurrent relays

机译:对定向过电力继电器最优协调问题中的瞬态配置的考虑

获取原文

摘要

An iterative methodology is presented to coordinate the operation of the directional overcurrent relays of a meshed system, considering the changes in the system topology, and therefore, the changes in the currents detected by the relays, that occur during the total fault clearing time, when only one of the main relays has operated (transient configurations). A linear programming algorithm is used to calculate the time dial settings that minimize the sum of the operation times of the relays of the system for the faults under study, subject to the time coordination constraints associated to each of the system configurations that take place during the fault clearing process, considering the limits on the relay settings allowed by the corresponding devices and the time-current characteristic associated to each of the relays. Two real cases are presented to illustrate the application of the methodology: an industrial 5 bus system, with two 115/13.8 kV power transformers, and a realistic transmission and sub transmission network consisting of an 18 bus system with 63 kV and 230 kV transmission lines, 13 power transformers and 96 directional overcurrent relays.
机译:考虑到系统拓扑的变化,介绍迭代方法以协调网状系统的定向过电流继电器的操作,因此,在总故障清除时间期间发生的继电器检测到的电流的变化。只有一个主继电器操作(瞬态配置)。线性编程算法用于计算最小化系统中继电器的操作时间总和的时间拨号设置,这对于在与期间发生的每个系统配置相关联的时间协调约束。故障清除过程,考虑相应设备允许的中继设置的限制以及与每个继电器相关联的时间电流特性。提出了两个实际情况以说明方法的应用:工业5个总线系统,具有两个115 / 13.8 kV电力变压器,以及由具有63kV和230 kV传输线的18个总线系统组成的现实传输和子传输网络,13电力变压器和96方向过电流继电器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号