This paper presents a method to design a robust dynamic compensator for reactive power modulation to improve the dynamic performance of an AC/DC power system. The robust dynamic compensator is designed using closed-loop eigenvalue sensitivity with respect to load characteristic. Eigenvalue analysis and simulation results show that a dynamic compensator designed using a constant impedance load model may lead to system instability at constant active power load. However, a robust dynamic compensator improves the system response over a wide range of load characteristics.
机译:本文介绍了一种设计鲁棒动态补偿器的方法,可用于改善AC / DC电力系统的动态性能。强大的动态补偿器使用闭环特征值相对于负载特性设计。特征值分析和仿真结果表明,使用恒定阻抗负荷模型设计的动态补偿器可能导致系统不稳定在恒定的电力负载下。然而,稳健的动态补偿器可以通过各种负载特性提高系统响应。