首页> 外文会议>IEEE Industry Applications Society Annual Meeting >Radiation pyrometry of glass during the container forming process
【24h】

Radiation pyrometry of glass during the container forming process

机译:玻璃辐射热测定在容器成型过程中

获取原文

摘要

When a narrowband infrared radiation pyrometer is used to measure glass temperature during the container forming process, the effects of glass color and thickness, pyrometer operating wavelength and emissivity setting, and background conditions must be considered when interpreting the results. A mathematical model is used to investigate the relative errors that these effects introduce into the measured temperature results. Techniques for controlling and/or compensating for them are suggested. Results are presented for both soda/lime flint and amber glasses with widely different infrared transmission characteristics, as well as for three different pyrometer operating wavelengths covering three distinct regions of their transmission spectrums. A temperature correction chart for indicated pyrometer readings is also presented.
机译:当窄带红外辐射高温计用于测量容器成型过程中测量玻璃温度时,在解释结果时,必须考虑玻璃颜色和厚度,高温计工作波长和发射率设定的影响,以及背景条件。数学模型用于研究这些效果引入测量温度结果的相对误差。提出了控制和/或补偿它们的技术。结果是苏打水/石灰燧石和具有广泛不同的红外传输特性的琥珀色眼镜,以及覆盖其传输光谱三个不同区域的三种不同的高温计工作波长。还介绍了指示的高温计读数的温度校正图。

著录项