After the loss of coolant accident (LOCA), the safety injection system injects water into the reactor coolant system (RCS). and the residual heat rejects from the break. The containment spray system is operating in recirculating cooling mode to ensure that the containment is cooldown. This state must be maintained for several months. After the accident, in order to respond the design extension conditions (DEC) of failure of two containment spray pumps or two low pressure safety injection pumps, the design of the original H4 connections was improved, and the H4 procedure (loss of containment spray pumps or low pressure safety injection pumps) was developed. H4 procedure demands to put into service 2 permanent (one for each train) interconnections of containment spray system and safety injection system, called "H4 connections". Through the design improvement of the H4 connections, the mutual backup function of safety injection and containment spray can be realized implemented. The manual valves of the H4 connections in the original design were changed to electric valves, which ensured the accessibility of operator and avoided the radiation of high radioactivity level to operator after the accident. In addition, the improved H4 connections enable mutual backup of safety-injection and containment spray in the early stage after the accident to be implemented, which fully improves the ability to respond to accidents and safety design level of the nuclear power plant (NPP). This also makes it possible to intervene early after the accident.
机译:在冷却剂事故(LOCA)丢失后,安全注入系统将水注入反应器冷却剂系统(RC)。并且残留的热量来自休息。电容喷雾系统在再循环冷却模式下操作,以确保容纳被冷却。必须保持该状态几个月。事故发生后,为了响应两个容纳喷雾泵的故障或两个低压安全喷射泵的设计扩展条件(DEN),原始H4连接的设计得到了改善,H4步骤(容纳喷雾泵的损失开发或低压安全喷射泵)。 H4程序要求投入服务2永久性(每列火车的一个)电容喷雾系统和安全注入系统的互连,称为“H4连接”。通过对H4连接的设计改进,可以实现安全喷射和容纳喷雾的相互备用功能。原始设计中的H4连接的手动阀门改为电阀,确保了操作员的可访问性,并在事故发生后避免了高放射性水平的辐射到操作员。此外,改进的H4连接能够在事故实施之后的早期阶段进行安全注入和遏制喷雾的相互备份,这完全提高了核电站(NPP)的事故和安全设计水平的能力。这也使得在事故发生后可能会介入。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号