A physical model with a scale of 1:20 was used to study the hydraulic characteristics of the flow in the forebay area of the pump station in Tian Wan Nuclear Power Plant Project Unit 5&6. The original layout scheme of the pump station forebay is limited by space, the turning radius of the intake gallery is small and the straight line section is short, the uniformity of water distribution is poor after seawater enters the forebay, the flow in the forebay cannot fully diffuse, the mainstream is concentrated, the flow distribution in the inlet section of each channel of the pump station is uneven, and the flow pattern is poor. Firstly, the distribution of water flow and uniformity of water distribution in the pump station forebay under different turning radius of tunnel are compared, and the turning radius of intake corridor is determined by calculating the head loss in different parts of tunnel. A variety of rectification facilities are arranged in the pumping station forebay, including modifying the grid type, setting diversion wall, diversion plate, energy dissipation beam, rectification bottom sill, etc. The recommended scheme is determined by hydraulic model test. The scheme can satisfy the requirement of uniformity of water distribution in the forebay, and the flow pattern along each section of the channel is also good.
机译:使用尺寸为1:20的物理模型来研究天湾核电站项目单元5&6中泵站前面积流动的液压特性。泵站的原始布局方案受空间的限制,进气廊的转弯半径很小,直线部分短,海水进入前平后,水分布的均匀性差,前平面的流量不能完全漫射,主流集中,泵站的每个通道的入口部分中的流动分布是不均匀的,并且流动模式差。首先,比较了隧道不同转动半径下泵站前水中水流量分布和水分布均匀性,通过计算隧道不同部分的头部损耗来确定进气走廊的转弯半径。在泵站前布置的各种整流设施,包括改变网格型,设定转移墙,转移板,能量耗散梁,整流底部窗台等。推荐方案是通过液压模型测试确定的。该方案可以满足前平水分布均匀性的要求,并且沿着通道的每个部分的流动模式也是良好的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号