首页> 外文会议>IEEE PELS Workshop on Emerging Technologies: Wireless Power Transfer >Phase Shift Control of a Three-Phase Inverter for Balanced Secondary Currents in Misaligned Three-Phase Inductive Power Transfer Systems
【24h】

Phase Shift Control of a Three-Phase Inverter for Balanced Secondary Currents in Misaligned Three-Phase Inductive Power Transfer Systems

机译:三相逆变器的相移控制在错位三相电感电力传输系统中的平衡二次电流

获取原文

摘要

This paper presents a strategy for generating fundamental reference voltage commands for a double-sided LCC tuned three-phase wireless power transfer (WPT) system to achieve balanced output currents when the receiver and transmitter are not perfectly aligned. Formulas for translating the normalized fundamental current commands into phase-shift commands for two of the phase legs in a two-level three-phase inverter are derived. The methodology is validated through circuit simulations performed using coupler models derived from finite-element simulations. Simulation results for a 1.5 k W system design are included, which indicate near perfect correction of imbalance in the secondary currents for a typical misalignment case.
机译:本文介绍了一种为双面LCC调谐三相无线电力传输(WPT)系统产生基本参考电压命令的策略,以实现当接收器和发射机不完美对齐时平衡输出电流。导出将归一化基本电流命令转换成两级三相逆变器中两个相位腿的相移命令的公式。通过使用从有限元模拟导出的耦合器模型执行的电路模拟来验证方法。包括1.5克W系统设计的仿真结果,这表明典型的错位情况下的二次电流中的不平衡完美校正。