The timing accuracy of a single-photon avalanche diode (SPAD) based receiver is analyzed as a function of excess bias voltage. The width of the used optical pulse was 100 ps, which matches well with the jitter of the used SPAD receiver fabricated in a 035 μm HVCMOS technology. The timing error was measured to be 900 ps within the excess bias voltage range of ~1.25 V - 3.25 V. The single-shot resolution changes from 420 ps to 160 ps (FWHM), respectively.
机译:分析了单光子雪崩二极管(SPAD)接收器的定时精度作为过度偏置电压的函数。所用光脉冲的宽度为100ps,与在035μmHVCMOS技术中制造的二手SPAD接收器的抖动很好地匹配。测量定时误差为900ps为900 ps,在〜1.25V-3.25 V的过度偏置电压范围内。单次分辨率分别从420 ps变为160 ps(fwhm)。