Industrial processes like milk production often require simultaneous cooling and heating at temperatureof 1 °C to 10 °C and 90 °C to 120 °C, respectively. High temperature heat pumps (HTHP) with naturalworking fluids are a cost-, energy efficient and sustainable solution.In this work a 20 kWth lab scale cascade heat pump is analysed to predict the performance of a 300 kWthpilot plant. The test campaign covers an evaporation temperature range of -1 °C to +1 °C and acondenser temperature range of 113 °C to 118 °C enabling ice-water chilling from 10 °C to 4 °C and ahot-water heating from 85 °C to 116 °CA Combined heating and cooling COPcombined of 2.6 to 2.8 was achieved for a temperature lift of110 K to 80 K, respectively. This performance gives a primary energy saving potential of 57% and apotential CO_2-emission reduction of 94%.It can be concluded that HTHP can produce simultaneously chilled/ice-water and hot-process waterefficiently for processes like drying, sterilization, pasteurization.
机译:牛奶生产等工业过程通常需要在温度下同时冷却和加热分别1°C至10°C和90℃至120℃。高温热泵(HTHP)与自然工作流体是一种成本,节能和可持续的解决方案。在这项工作中,分析了20 kWth实验室规模级联热泵,以预测300 kWth的性能试验工厂。测试活动涵盖-1°C至+1°C和a的蒸发温度范围冷凝器温度范围为113°C至118°C,使冰水从10°C冷却至4°C和a热水加热85°C至116°C对于温度升力,实现了2.6至2.8的组合加热和冷却型为2.6至2.8110 k至80 k分别。这种性能给出了57%的主要节能潜力和a潜在的CO_2 - 减排94%。可以得出结论,HTHP可以同时生产冷藏/冰水和热处理水有效地用于干燥,灭菌,巴氏灭菌等方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号