Shunt Passive Filters (SPF) are an economically well-founded and technically effective solution for reactive power compensation and solving the problems with harmonics, caused by non-linear loads, in the electrical power systems of medium and large industrial enterprises. The elements parameters definition for each SPF is a specific task that is specifically solved for each power supply system.This paper presents a methodology, algorithm and software program for designing Medium Voltage (MV) filter-compensating devices. Particular attention is paid to the determination and distribution of the compensating power among the different harmonic filters. The results from this work can be useful in designing and optimizing the efficiency of the medium voltage shunt passive filters.
机译:分流无源过滤器(SPF)是一种经济上良好的,技术有效的反应功率补偿解决方案,并解决了由非线性负载引起的谐波的问题,中型和大型工业企业的电力系统。每个SPF的元素参数定义是针对每个电源系统专门解决的特定任务。本文提出了一种用于设计中电压(MV)滤波器补偿装置的方法,算法和软件程序。特别注意不同谐波滤波器之间的补偿功率的确定和分布。该工作的结果可用于设计和优化中压分流无源滤波器的效率。