Partial Discharge Properties in XLPE Block Sample with Electric Tree Defect and Difference in Charge of PD Properties Observed between IEC60270 and the UHF Method

机译:XLPE块样品中的局部放电特性,具有电动树缺陷和IEC60270和UHF方法之间观察到的PD特性差异

获取原文

摘要

XLPE power cables are widely used in the transmission and distribution network and required high reliability for the stable and safety operation in the power system. This paper described partial discharge properties of XLPE block sample with a needle stuck defect, which eventually initiated electric tree by applying ac high voltage, measured with two methods: one is a conventional method followed by IEC60270 standard (IEC method) and the other is the UHF method to measure the emitted electromagnetic waves. In the IEC method, the authors have used PD measurement systems (OMICRON, MPD600) and measured the signals through a high-frequency current transformer, CT, a coupling capacitor unit, CC and an HA antenna with a UHF unit. Applying the system, the phase-resolved PD pattern, and its time change pattern for the XLPE samples were observed. In the UHF method, we used the HA antenna and a MA antenna, and a digital oscilloscope. Using the fast flame function of the oscilloscope, we observed the time change of PD-emitted electromagnetic waves together with the IEC method measurement. As a result, in the IEC method, the observed signals by the CC and CT were identical in PD pattern and the intensity, and their properties changed depending on the sample condition even in the tree initiation condition. However, the remarkable change was not found during the developing tree condition. To investigate this property further, we investigated the properties by the UHF method and compared them together with the PD current waveform measurement. Based on the PD current properties, the advantage of the UHF method and problem of the IEC method were discussed so as to evaluate the PD properties even in the developing tree condition.
机译:XLPE电力电缆广泛用于传输和配电网络,并且需要高可靠性,以便在电力系统中稳定和安全操作。本文描述了用针卡缺陷的XLPE块样品的局部放电特性,其最终通过施加AC高压来启动电动树,用两种方法测量:一个是传统方法,然后是IEC60270标准(IEC方法),另一个是IEC60270标准(IEC方法)。 UHF测量发出的电磁波的方法。在IEC方法中,作者使用了PD测量系统(OMICRON,MPD600)并通过高频电流互感器,CT,耦合电容器单元,CC和具有UHF单元的HA天线测量信号。观察到XLPE样本的相位分辨PD图案及其时间变化模式。在UHF方法中,我们使用了HA天线和MA天线,以及数字示波器。使用示波器的快速火焰功能,我们观察了PD发射电磁波与IEC方法测量的时间变化。结果,在IEC方法中,CC和CT的观察到的信号在PD图案和强度中相同,并且它们的性质也根据树木启动条件而变化。但是,在发育中的树木条件下找不到显着的变化。要进一步调查此属性,我们通过UHF方法调查了该性质,并将其与PD电流波形测量相结合。基于PD电流特性,讨论了UHF方法的优点和IEC方法的问题,以便在显影树条件下评估PD特性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号