摘要

This paper represents the polarization and depolarization current (PDC) characteristics of natural ester impregnated pressboards with different impregnation period. The pressboard specimen were prepared as a rectangular shape (the length and the width are 120 mm as well) and thickness dimension of the pressboard in the experiment was approximately 1.6 mm. The pressboards were dried up in the vacuum oven with temperature at 80°C for 12 hours under 200 mbar pressure. In addition, these pressboards were divided into 3 groups according to the impregnation periods. The 1st group, the pressboard was non-impregnated with natural ester. The 2nd and 3rd group, the pressboards were impregnated at 60°C for 8 and 16 hours, respectively, under 200 mbar pressure-controlled condition. The plane-plane electrodes inserted with the specified number of the pressboard specimens were prepared. These electrodes were installed in the test cell filled with the natural ester. A 24 kV AC Voltage was applied to the test cell for 3 months. At the end of the first month, half of the pressboard samples was token from the test cells. Then, the PDC characteristics of these natural ester impregnated pressboards were investigated. At the end of the third month, another half of the pressboard samples was token from the test cells to perform PDC measurement also. It was found that the PDC values of the pressboards with longer period impregnation process were lower than these of the pressboards with longer period impregnation process. Besides, the PDC values of the pressboards experienced with longer electric field stress period (3 months) were higher than these of the pressboards experienced with shorter electric field stress period (1 month).
机译:本文表示天然酯的极化和去极化电流(PDC)特性浸渍pressboards具有不同浸渍周期。压板样品制备为矩形形状(长度和宽度是120毫米以及)和在实验中压板的厚度尺寸为约1.6毫米。所述pressboards中在80℃与温度的烘箱中在200毫巴压力12小时真空干燥的。此外,这些pressboards根据浸渍周期分为3组。 1 st 组,所述压板是非浸渍有天然酯。 2 nd 和3. rd 组,所述pressboards在60浸渍℃8小时和16小时,分别200毫巴压力控制条件下进行。制备插入有所述压板标本的指定数值的平面的面内电极。这些电极分别安装在填充有天然酯的测试电池。 24千伏交流电压施加到测试单元为3个月。在第一个月的月底,纸板样品的一半从测试的细胞标记。然后,将这些天然酯浸渍pressboards的PDC特性进行研究。在第三个月结束时,压制板样品的另一半从测试细胞令牌为还执行PDC的测量。结果发现,用更长的时间浸渍过程中pressboards的PDC值比那些在较长时期浸渍过程中pressboards低。此外,pressboards的PDC值具有较长电场应力期间(3个月)比这些更短的电场应力期间(1个月)所经历的pressboards的较高经验。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号