首页> 外文会议>IEEE International Conference and Workshop in Qbuda on Electrical and Power Engineering >Extended Voltage Response Measurement of Low Voltage Nuclear Power Cables Under Simultaneous Thermal and Mechanical Aging
【24h】

Extended Voltage Response Measurement of Low Voltage Nuclear Power Cables Under Simultaneous Thermal and Mechanical Aging

机译:低压核电缆在同时热和机械老化下的延长电压响应测量

获取原文

摘要

For reliable and safe operation of nuclear power plants, all components must fulfill their intended function over their whole lifetime. This involves a large scale of low voltage cables based polymeric insulation. During the normal operation of nuclear power plants, the insulating materials degrade due to several stresses. Therefore, monitoring the insulation integrity of cables is of utmost importance. In this work, low voltage cable samples used in nuclear facilities were exposed to simultaneous thermal and mechanical accelerated aging. The combined aging effect on the cable's insulation condition was based on the measurement of return and decay voltages slope. With the aging period increased, a decreasing fashion was observed for the return voltage slope. While on the contrary, the voltage decay slope increased.
机译:为了可靠和安全的核电厂运行,所有组件必须在整个寿命中满足其预期的功能。这涉及基于大规模的基于低压电缆的聚合物绝缘。在核电站的正常运行期间,由于若干应力,绝缘材料降低。因此,监测电缆的绝缘完整性至关重要。在这项工作中,核设施中使用的低压电缆样品暴露于同时热和机械加速老化。对电缆绝缘条件的综合老化效果基于返回和衰减电压斜率的测量。随着老化期的增加,返回电压斜率观察到减少的方式。虽然相反,电压衰减斜率增加。