首页> 外文会议>Electromagnetic Compatibility, 2000. IEEE International Symposium on >Measurements of transfer impedance with the line injection methodon cables and connectors
【24h】

Measurements of transfer impedance with the line injection methodon cables and connectors

机译:使用线路注入法测量传输阻抗在电缆和连接器上

获取原文

摘要

In an electronic system the connection cables and the relevantconnectors have been recognized as one of the main causes ofinterference in different apparatus. Different methods are used toevaluate the shielding effectiveness of cables and connectors. In thispaper the method of the line injection is addressed and the results ofmeasurements on a number of samples of cables and connectors arepresented. The measurements on the same samples were carried out in twodifferent laboratories in order to assure the reliability of the method
机译:在电子系统中,连接电缆和相关的 连接器已被认为是导致连接器损坏的主要原因之一 在不同设备中的干扰。使用不同的方法来 评估电缆和连接器的屏蔽效果。在这个 论文讨论了线注入的方法,并得到了结果。 在许多电缆和连接器样品上进行的测量是 提出了。同一样品的测量分两次进行 不同实验室以确保方法的可靠性