首页> 外文会议>Intelligent Control and Automation, 2006. WCICA 2006. The Sixth World Congress on >Fault Diagnosis of Reverse Osmosis System for Chemical Water Treatment in Power Plant Based on FMEA and Rough Set Theory
【24h】

Fault Diagnosis of Reverse Osmosis System for Chemical Water Treatment in Power Plant Based on FMEA and Rough Set Theory

机译:基于FMEA和粗糙集理论的电厂化学水反渗透系统故障诊断。

获取原文

摘要

Aiming at the problem of redundant symptoms and incomplete information when diagnosing the fault of reverse osmosis system for chemical water treatment in power plant using the result of failure mode and effect analysis. A fault diagnosis method of RO system is proposed based on rough set theory. By analyzing the classical failure modes of RO system, fault diagnosis decision table is built, then fault symptom attributes reduction is made, and the fault diagnosis rules are gained. An instance analysis of a RO system is made, the result shows that this method is feasible and effective and can fulfil the fault diagnosis of RO system and can be a support for making decision for cleaning and maintenance
机译:针对利用故障模式和效果分析结果诊断电厂化学水处理反渗透系统故障时出现的冗余症状,信息不全的问题。提出了基于粗糙集理论的反渗透系统故障诊断方法。通过分析RO系统的经典故障模式,建立故障诊断决策表,对故障征兆属性进行归约,得到故障诊断规则。通过对RO系统的实例分析,结果表明该方法可行,有效,可以完成RO系统的故障诊断,为清洗维修决策提供依据。