摘要

A drop in power frequency indicates a deficiency of power in thegrid. Attempts are made to offset this drop by means of graded measuresranging from warning staff and the use of all available power-generationreserves, to load-shedding. If, despite all counter-measures, the dropin frequency cannot be stopped and the probability of a total powerfailure arises, municipal or regional energy utilities withpower-generation facilities close to their consumers can isolatethemselves from the grid and thus create a grid island. Taking theTechnische Werke der Stadt Stuttgart AG (TWS) as an example, the authorsshow how even stations further afield can be integrated into this gridisland, which technical boundary conditions have to be observed whendoing so, and how this concept was realized. They also look at there-establishment of the grid subsequent to such a case of isolation, oreven after a total power failure
机译:功率频率的下降表示电源中的功率不足 网格。试图通过分级措施来弥补这一下降 包括预警人员和使用所有可用的发电设备 储备,以减轻负荷。尽管采取了所有对策,但如果 频率不能停止并且总功率的概率 出现故障,市政或区域能源公用事业 靠近消费者的发电设施可以隔离 从网格本身,从而创建一个网格岛。以 作者以斯图加特工业技术大学(TWS)为例 展示甚至更远的站点如何可以集成到此网格中 岛,在什么情况下必须遵守哪些技术边界条件 这样做,以及如何实现这一概念。他们还看了 在这种隔离情况之后重新建立网格,或者 即使完全断电之后