This paper presents a control approach for a single switch inverter. The inverter exhibits non-minimum phase behavior in some of the operating modes. A dual feedforward controller was employed with an adaptive PI controller to obtain perfect tracking performance. The controller successfully isolates the non-minimum phase part of the system from the minimum phase. Both separated minimum phase and non-minimum phase sub-systems were used in the dual feedforward scheme to generate desired references. The non-minimum phase dynamics are transformed to minimum phase by using an inverse system transfer function as parallel compensator. The adaptive PI controller was used to track the voltage references.
机译:本文提出了一种用于单开关逆变器的控制方法。在某些操作模式下,逆变器表现出非最小相位行为。双前馈控制器与自适应PI控制器一起使用,以获得完美的跟踪性能。控制器成功地将系统的非最小相位部分与最小相位隔离。在双前馈方案中使用了分离的最小相位子系统和非最小相位子系统,以生成所需的参考。通过使用逆系统传递函数作为并行补偿器,可以将非最小相位动力学转换为最小相位。自适应PI控制器用于跟踪参考电压。