Impulse energy is one of the most important parameters that need to be calibrated for defibrillator and defibrillator analyzer. The measurement accuracy of commercial defibrillator analyzer could reach ± 1 % of reading plus 0.1 Joule nowadays. So, it placed a greater demand on the measurement standard used for the calibration. In the National Institute of Metrology (NIM) China, we had developed a set of national measurement standard. The calibration uncertainty on the defibrillator analyzer is evaluated to be better than 0.06% of reading plus 0.06 Joule. In this manuscript, the components of the system and the uncertainty evaluation of the measurement standard is introduced.
机译:脉冲能量是除颤器和除颤器分析仪需要校准的最重要参数之一。如今,商用除颤器分析仪的测量精度可以达到读数的±1%,再加上0.1焦耳。因此,它对用于校准的测量标准提出了更高的要求。在中国国家计量学会(NIM)中,我们制定了一套国家测量标准。除颤器分析仪的校准不确定度被评估为优于读数的0.06%加上0.06焦耳。在本文中,介绍了系统的组成部分和测量标准的不确定度评估。