Four-scanning-heads error separation method under optimal arrangement has proven useful for measuring the radial error motion of axis of rotation. This technique is based upon the fact that angles read by scanning heads are mainly affected by both the graduation error of the angle encoder's scale and the spindle radial error motion. This paper presents a further validation of this method on a high-accuracy air-bearing rotary stage equipped with an angle encoder with six scanning heads. Experiments are performed to measure the radial error motion by three different four-scanning-heads arrangement schemes. The results show a nanometer-level repeatability of the measured error motion. Moreover, the error motion values obtained by these three arrangement schemes agree very well, which further confirm the effectiveness of the method. This technique is well suited for error motion measurement of rotary tables with angle encoder as the angle measuring device, since it needs no additional artifact compared with the conventional methods.
机译:事实证明,采用最佳布置的四扫描头误差分离方法可用于测量旋转轴的径向误差运动。该技术基于以下事实:扫描头读取的角度主要受角度编码器刻度尺的分度误差和主轴径向误差运动的影响。本文介绍了这种方法在配备有六个扫描头的角度编码器的高精度空气轴承旋转工作台上的进一步验证。通过三种不同的四扫描头布置方案进行了测量径向误差运动的实验。结果显示了所测量误差运动的纳米级可重复性。此外,通过这三种布置方案获得的误差运动值非常吻合,这进一步证实了该方法的有效性。该技术非常适合使用角度编码器作为角度测量设备的旋转工作台的误差运动测量,因为与传统方法相比,它不需要额外的伪像。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号