首页> 外文会议>SPIE Defense + Commercial Sensing Conference;Society of Photo-Optical Instrumentation Engineers >From the Warehouse to the Field – New Applications of Existing Chemical Warfare Agent Detectors without Hardware Modification
【24h】

From the Warehouse to the Field – New Applications of Existing Chemical Warfare Agent Detectors without Hardware Modification

机译:从仓库到现场-无需修改硬件的现有化学战代理探测器的新应用

获取原文

摘要

The initial objective of this work was to demonstrate detection of explosives and precursor materials using existing, fieldedCWA (Chemical Warfare Agent) point detection systems, specifically the Joint Chemical Agent Detector (JCAD), and tointegrate explosives detection into the family of CBRN sensors. A key premise of the objective is to demonstrate this utilitywithout modifying the detector itself. Recent RDECOM efforts expanded to demonstrate the ability of the JCAD to detectand analyze explosives, low volatility compounds (LVC), narcotics, and pharmaceutical based compounds (PBC) in thismanner. JCAD is a currently fielded, man-portable, ion mobility spectrometry-based detector for CWA that operates atambient atmospheric pressure conditions.Tens of thousands JCAD systems have been produced and many remain in warehouse storage. Smiths Detection andRDECOM have produced a new chemical detector system using an unmodified JCAD. A JCAD from the warehouse canbe plugged into a new solid-liquid adapter (SLA) peripheral hardware, or “cradle,” and analysis software residing in thecradle turns the JCAD into a detector for explosives, LVC, narcotics, and PBC.The system has been demonstrated for trace detection of these compounds. To maintain high versatility and lowinterferences, its spectrometric resolving power is improved through rigorous instrument calibration and real-time signalprocessing techniques. Separate unique instrumentation to measure ion mobility values an order of magnitude moreaccurately (± 0.2%) than literature values is in operation at ECBC and provides the reference values for JCAD calibration.Measured ion mobility values of target analytes are adjusted for water vapor effects and background contaminants duringcalibration.
机译:这项工作的最初目的是证明使用现有的已实地侦查爆炸物和前体材料的能力。 CWA(化学战剂)点检测系统,特别是联合化学剂检测器(JCAD),以及 将爆炸物检测功能集成到CBRN传感器系列中。目标的关键前提是演示此实用程序 无需修改检测器本身。 RDECOM最近的努力扩大了规模,以展示JCAD的检测能力 并在此分析爆炸物,低挥发性化合物(LVC),麻醉品和基于药物的化合物(PBC) 方式。 JCAD是一种用于CWA的,现成的,基于人便携式的,基于离子迁移谱的检测器,可在以下条件下运行 环境大气压力条件。 已经生产了成千上万的JCAD系统,许多仍保留在仓库中。史密斯检测和 RDECOM使用未经修改的JCAD生产了一种新的化学检测器系统。仓库中的JCAD可以 插入新的固液适配器(SLA)外围硬件或“通讯座”,以及位于计算机中的分析软件 摇篮将JCAD变成爆炸物,LVC,麻醉品和PBC的探测器。 该系统已被证明可用于这些化合物的痕量检测。保持高通用性和低 干扰,其光谱解析能力通过严格的仪器校准和实时信号得到改善 处理技术。单独的独特仪器可测量离子迁移率值一个数量级 在ECBC上运行时,其准确度(比文献中的值高±0.2%)为JCAD校准提供了参考值。 在分析过程中,针对水蒸气效应和背景污染物对目标分析物的离子迁移率测量值进行了调整 校准。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号