The liquid crystal phase shifter integrates the technologies of the liquid crystal display and radar antenna. It belongs to abrand-new interdisciplinary research field. The traditional leakage rate test method of electronic components is not suitablefor the liquid crystal phase shifter. The liquid crystal phase shifter and liquid crystal display have similar structures andthey are sealed by sealant, so, this article adopts the saturated vapor experiment and liquid crystal display material physicalproperties test method to make a theoretical research and experimental verification for the leak rate of the liquid crystalphase shifter. In this paper, we set up a kind of theoretical model for the liquid crystal phase shifter leak rate test and realizethe actual measurement for the theoretical model. The test results comply with expected judgment, which shows that thetheoretical model works, and the test results have actual guiding significance for the material and technological selectionfor producing liquid crystal phase shifters.
机译:液晶移相器集成了液晶显示器和雷达天线的技术。它属于 全新的跨学科研究领域。电子元件的传统泄漏率测试方法不适合 用于液晶移相器。液晶移相器和液晶显示器具有相似的结构,并且 它们被密封剂密封,因此,本文采用饱和蒸气实验和物理的液晶显示材料 特性测试方法,对液晶的泄漏率进行理论研究和实验验证 移相器。本文建立了液晶移相器泄漏率测试的理论模型,并实现了 理论模型的实际测量值。测试结果符合预期判断,表明 理论模型工作,试验结果对材料和工艺选择具有实际指导意义 用于生产液晶移相器。