An ultra-low emission Cl_2 monitoring optical system based on differential optical absorption spectroscopy has beenset up. We have found through comparison experiments that UV reflection enhanced aluminum is damaged and thedielectric film mirror is intact under high concentration of Cl_2. Then verify the performance characteristics of ultralowCl_2 emission online monitoring device. The maximum absorbance of 50ppm Cl_2 exceeds 0.1, while the 30ppmCl_2 reaches 0.063, so the measurement range can be 0-95 mg/m~3, which meets the maximum allowable emissionconcentration of Cl_2 required by the new regulations for detection of 65mg/m~3.
机译:基于差分吸收光谱法的超低发射Cl_2监测光学系统已经研制成功。 设置。通过比较实验,我们发现紫外线反射增强型铝被损坏,并且 在高浓度的Cl_2下,电介质膜镜是完整的。然后验证超低的性能特征 Cl_2排放在线监测装置。 50ppm Cl_2的最大吸光度超过0.1,而30ppm Cl_2达到0.063,测量范围为0-95 mg / m〜3,满足最大允许发射量 新法规要求的Cl_2浓度为65mg / m〜3。