首页> 外文会议>Conference on Medical Imaging: Image Processing >Establishing Surface Correspondence for Post-surgical Cortical Thickness Changes in Temporal Lobe Epilepsy
【24h】

Establishing Surface Correspondence for Post-surgical Cortical Thickness Changes in Temporal Lobe Epilepsy

机译:建立颞叶癫痫患者后手术后皮质厚度变化的表面对应

获取原文

摘要

In pre- and post-surgical surface shape analysis, establishing shape correspondence is necessary to investigate the postoperative surface changes. However, structural absence after the operation accompanies focal non-rigid changes, which leads to challenges in existing surface registration methods. In this paper, we present a fully automatic particle-based method to establish surface correspondence that can handle partial structural abnormality in the temporal lobe resection. Our method optimizes the coordinates of points which are modeled as particles on surfaces in a hierarchical way to reduce a chance of being trapped in a local minimum during the optimization. In the experiments, we evaluate the effectiveness of our method in comparison with conventional spherical registration (FreeSurfer) on two scenarios: cortical thickness changes in healthy controls within a short scan-rescan time window and patients with temporal lobe resection. The post-surgical scan is acquired at least 1 year after the presurgical scan. In region of interest-wise (ROI-wise) analysis, no changes on cortical thickness are found in both methods on the healthy control group. In patients, since there is no ground truth available, we instead investigated the disagreement between our method and FreeSurfer. We see poorly matched ROIs and large cortical thickness changes using FreeSurfer. On the contrary, our method shows well-matched ROIs and subtle cortical thickness changes. This suggests that the proposed method can establish a stable shape correspondence, which is not fully captured in a conventional spherical registration.
机译:在前手术后表面形状分析中,建立形状对应是研究术后表面的变化。然而,在操作后的结构缺席伴随着焦点非刚性变化,这导致现有的表面登记方法中的挑战。在本文中,我们提出了一种全自动粒子的方法,以建立可以处理时间叶切除中的部分结构异常的表面对应。我们的方法优化了点的点坐标,其以分层方式在表面上以粒子建模,以减少在优化期间以局部最小捕获的可能性。在实验中,我们在两种情况下评估了我们的方法的有效性与传统的球面注册(FreeSurfer)进行了比较:短扫描 - Rescan时间窗口内健康控制的皮质厚度变化,颞叶切除患者。在预设扫描后至少1年内获得手术后扫描。在感兴趣的(ROI-WISE)分析区域中,在健康对照组的两种方法中没有发现皮质厚度的变化。在患者中,由于没有地面真相,我们调查了我们的方法和弗雷德利夫之间的分歧。我们看到ROIS匹配差,使用FRESURER匹配的巨大皮质厚度变化。相反,我们的方法显示出良好的ROI和微妙的皮质厚度变化。这表明该方法可以建立稳定的形状对应关系,其在传统的球面注册中不完全捕获。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号