In this paper, one-time tube sealing and exhausting of 72.5kV ceramic vacuum interrupter is studied. The QMG220 quadrupole mass spectrometer was used to detect and record the residual gas in the 72.5kV vacuum interrupter during the whole process of sealing. By analyzing the rule of the exhaust gas in the process of baking, the kinds of residual gas and the partial pressure of the residual gas in the product are obtained. Through experimental analysis, the sealing and discharging process of 72.5kV vacuum interrupter is optimized, and establish the process curve of temperature rise, heat preservation and temperature drop for one-time tube sealing and exhausting of 72.5kV ceramic vacuum interrupter. The results of mass spectrum analysis show that the residual gases in 72.5kV vacuum interrupter are mainly H2, H2O, CO and CO2.
机译:本文研究了一次72.5kV陶瓷真空灭弧室的一次密封与排气。在整个密封过程中,使用QMG220四极质谱仪检测并记录72.5kV真空灭弧室中的残留气体。通过分析烘烤过程中废气的规律,得出产品中残留气体的种类和残留气体的分压。通过实验分析,对72.5kV真空灭弧室的充放电过程进行了优化,建立了72.5kV陶瓷真空灭弧室一次密封和排气的升温,保温和降温过程曲线。质谱分析结果表明,在72.5kV真空灭弧室中的残留气体主要为H。 2 , H 2 O,CO和CO 2