首页> 外文会议>International Conference on Electrical Engineering and Computer Science >Low Cost Transient Earth Voltage Probe for Partial Discharge Detection
【24h】

Low Cost Transient Earth Voltage Probe for Partial Discharge Detection

机译:用于局部放电检测的低成本瞬态接地电压探头

获取原文
获取外文期刊封面目录资料

摘要

Partial discharge (PD) that occurs in enclosed metal equipment such as air-insulated switchgear is unpredictable and causes the failure of an insulation system. This PD emits electromagnetic field and hence can be detected through a capacitive sensor mounted on the wall. Thus, it is suitable to detect and monitor internal PD activity in an enclosed metal equipment using Transient Earth Voltage (TEV) probe. Therefore, this study aims to implementing TEV probe which has been developed at a low cost to detect the partial discharge occurs in enclosed metal equipment. It involved the characterization of the parameter of the probe and also the measurement of TEV based on IEC TS 62478 standard. In addition, the spectral density and phase-resolved partial discharge pattern of the developed TEV probe were analyzed and compared with the commercial TEV. The time-resolved pattern of the partial discharge was also recorded to monitor the PD pulses in one full cycle. As a result, it was found the partial discharge was able to be detected through this developed TEV probe with acceptable PD patterns.
机译:在封闭的金属设备(例如,空气绝缘的开关设备)中发生的局部放电(PD)是无法预测的,并且会导致绝缘系统故障。该PD会发射电磁场,因此可以通过安装在墙上的电容式传感器进行检测。因此,适合使用瞬态接地电压(TEV)探针检测和监视封闭式金属设备中的内部PD活性。因此,本研究旨在实施TEV探头,该探头已经以低成本开发出来,可以检测出封闭式金属设备中发生的局部放电。它涉及探头参数的表征以及基于IEC TS 62478标准的TEV的测量。此外,分析了开发的TEV探针的光谱密度和相分辨的局部放电模式,并将其与商用TEV进行了比较。还记录了部分放电的时间分辨模式,以在一个完整的周期内监视PD脉冲。结果,发现可以通过这种开发的TEV探头以可接受的PD模式检测局部放电。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号