首页> 外文会议>Air and Waste Management Association annual conference and exhibition >Emission Control of Halogenated Anesthetic Gases in Hospital Air
【24h】

Emission Control of Halogenated Anesthetic Gases in Hospital Air

机译:医院空气中卤化麻醉气体的排放控制

获取原文

摘要

This work demonstrated that it was feasible to capture more dilute concentrations of the fluorinated ether anesthetic gases from a hospital ventilation system, using commercial activated carbon. The quantified adsorption capacity was satisfactory for use over a period of several weeks, and it was feasible to use thermal desorption at relatively mild temperatures to regenerate the carbon for re-use. Low temperature condensation of the anesthetics during carbon desorption could recover a substantial fraction, and this may be a basis for the operation of a commercial system. Further work on commercialization and recycling of anesthetic compounds continues.
机译:这项工作表明,使用商业活性炭捕获来自医院通风系统的氟化醚麻醉气体的更稀释浓度是可行的。在几周内使用量化的吸附容量令人满意,并且在相对温度温度下使用热解吸以再生碳以进行再使用。在碳解吸期间的麻醉剂的低温凝结可以恢复大量分数,这可能是商业系统操作的基础。进一步研究了商业化和戒毒化合物的回收。