We propose a new high-resolution TOF PET detector, a "side-by-side phoswich detector", where two crystals with fast and slow decay time are side-coupled to a row of photosensors. Monte Carlo simulation was conducted to find the optimal conditions for a side-by-side phoswich design. Then a proof-of-concept PET detector was built comprising two 1.9×1.9×10 mm3 LSO crystals (τ_d=34.39 and 43.07 ns) sidecoupled with three 4×4 mm2 SensL SiPMs. A CTR of 107.07 ps was achieved at 32V bias voltage with a 2 mV leading edge threshold for the side-by-side phoswich configuration. The side-by-side phoswich detector showed good energy resolution of 10.35% at 511 keV and good crystal separation in two 1.9×1.9×10 mm3 crystals with different decay time when we applied the time-over-threshold technique. These results indicate we can achieve high resolution, 10% energy resolution and 100-ps coincidence timing resolution (CTR) all at once.
机译:我们提出了一种新的高分辨率TOF PET检测器,即“并排式荧光检测器”,其中两个具有快速衰减时间和缓慢衰减时间的晶体被侧面耦合到一排光电传感器上。进行了蒙特卡洛模拟,以发现并排磷光体设计的最佳条件。然后建立了一个概念验证的PET探测器,该探测器包括两个1.9×1.9×10 mm 3 LSO晶体(τ_d= 34.39和43.07 ns)与三个4×4 mm侧面耦合 2 SensL SiPM。在32V偏置电压下,对于并排的phoswich配置,CTR为107.07 ps,前沿阈值为2 mV。并排式荧光检测器在511 keV时显示出10.35%的良好能量分辨率,并且在两个1.9×1.9×10 mm中具有良好的晶体分离 3 当我们应用阈值以上时间技术时,具有不同衰减时间的晶体。这些结果表明,我们可以同时实现高分辨率,10%的能量分辨率和100ps的重合时序分辨率(CTR)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号