Reinforced concrete cooling towers exposed to harsh operating environments can develop severe corrosion of embedded steel reinforcing, concrete delamination and spalling. Condition assessment of cooling towers is challenging due to their size, geometry and operational constraints but careful investigation can provide critical knowledge to effectively characterize structural health, plan maintenance, and prioritize repairs to maximize service life. A case history is presented to illustrate how assessment data was collected, interpreted, and used to develop and implement repair strategies for two 400 foot (121 m) tall hyperbolic shell cooling towers exhibiting widespread corrosion-induced deterioration. Evaluation of concrete properties, corrosion rate and desired service-life objectives were considered in the decision to utilize impressed current cathodic protection (ICCP) and galvanic cathodic protection (GCP) as part of the repair program. Review of the design and installation of the ICCP and GCP systems highlight the unique challenges associated with repair and protection of reinforced concrete cooling towers.
机译:暴露于恶劣工作环境中的钢筋混凝土冷却塔会严重腐蚀嵌入式钢筋,混凝土分层和剥落。由于冷却塔的尺寸,几何形状和操作限制,其状态评估具有挑战性,但是仔细的调查可以提供关键知识,以有效地表征结构健康状况,计划维护并确定维修优先级以最大限度地延长使用寿命。介绍了一个案例历史,以说明如何收集,解释评估数据,并用于开发和实施两个400英尺(121 m)高的双曲线壳体冷却塔的修复策略,这些冷却塔表现出广泛的腐蚀引起的劣化。在决定采用外加电流阴极保护(ICCP)和电流阴极保护(GCP)作为修复计划的一部分的决定中,考虑了混凝土性能,腐蚀速率和所需使用寿命目标的评估。对ICCP和GCP系统的设计和安装的审查突出了与钢筋混凝土冷却塔的维修和保护相关的独特挑战。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号