首页> 外文会议>Advanced machinery technology symposium >Measurement of Current Sharing in Multi-Parallel Cell Batteries
【24h】

Measurement of Current Sharing in Multi-Parallel Cell Batteries

机译:多并联电池中电流共享的测量

获取原文

摘要

1. Measurable current imbalance measured on both 1S30P and 1S4P lithium-ion cell arrays at UTA and NRL, respectively 2. Current imbalance is measured from start to finish, even when cells are carefully binned into matched parallel arrays 3. Data suggests that a lack of monitoring in high parallel count arrays results in the inability to detect pending cell end of life 4. Results at both UTA and NRL have shown that low C EIS and DC-ESR measurements are not good metrics for binning cells 5. It is speculated that the imbalance in cell SoC may induce higher stress on certain cells 6. There is no smoking gun that indicates what causes the imbalance or that it leads to severe uneven aging.
机译:1.在UTA和NRL的1S30P和1S4P锂离子电池阵列上分别测得的可测量电流不平衡2.即使从头到尾将电池小心地装到匹配的并联阵列中,也要从头到尾测量电流不平衡3.数据表明缺乏高并行计数阵列中的监视结果导致无法检测到即将终止的电池寿命4。UTA和NRL的结果均表明,低C EIS和DC-ESR测量值不是对电池5进行分箱的良好指标。据推测,电池SoC中的不平衡可能会导致某些电池6承受更高的压力。没有吸烟枪可以指示导致不平衡的原因或导致严重不均匀老化的原因。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号