摘要

Electromagnetic compatibility between the running of subway train and exterior space is related to driving safety and stability. The countermeasures on the EMI characteristics are becoming main technique points. The EMI Test results of one subway train about 9k-1GHz show that EMI of 150k-1.15MHz exceed the limit. The DC input side of inverter is identified as the main EMI resource after studying and analyzing the EMI resources of the whole train and electromagnetic propagation path. The parameters of safety capacitor is confirmed by exceeding frequency and electrical parameters of inverter as well as main circuit configuration of the whole train. Field test data which meet standard requirement indicate that the safety capacitor optimize EMI of the whole train.
机译:地铁列车运行与外部空间之间的电磁兼容性与行驶安全性和稳定性有关。 EMI特性的对策正成为主要技术要点。一辆大约9k-1GHz的地铁列车的EMI测试结果表明,150k-1.15MHz的EMI超过了限值。通过研究和分析整列和电磁传播路径的电磁干扰资源,可以确定逆变器的直流输入侧为主要的电磁干扰资源。安全电容器的参数是通过超过变频器的频率和电气参数以及整个列车的主电路配置来确定的。符合标准要求的现场测试数据表明,安全电容器可优化整个列车的EMI。